Complete certified doorsetsFree measure surveyEngland, Wales, Scotland & NI
Call 0800 088 6248
Fire Rated Doors
FD30SWide leavesKick plates

School & Healthcare Fire Doors in Hayes

We supply and fit school fire doors in Hayes (UB3) as complete certified doorsets — with a free measure survey, a fixed itemised quote listing every certificate reference, and installation exactly as tested.

From £1,100 per doorset in Hayes, supplied & fitted, ex VAT

Wide double timber fire doors with vision panels and kick plates in a school corridor

Certified school fire doors for Hayes

Need school fire doors in Hayes? We supply and fit complete certified doorsets across Greater London, starting with a free measure survey in and around UB3. Every quote lists each door, its rating and the manufacturer's certificate reference, so you know exactly what is going in before anything is ordered.

Where possible we combine Hayes surveys with other visits in Greater London, such as Southall and Heston, which helps keep survey dates flexible.

Regulations for school fire doors in Greater London

In Hayes, as across England, Approved Document B governs new work and the Fire Safety Order 2005 governs existing premises. Note that Approved Document B is removing the BS 476 fire-resistance test references on 2 September 2029, so specifications are moving to EN classifications such as E30 Sa.

What do school fire doors cost in Hayes?

Budget around £1,100 to £2,400 per doorset for school fire doors supplied and fitted in Hayes, excluding VAT. We price each opening separately so nothing is hidden in a lump sum.

Central and inner London work can cost a little more where parking, loading restrictions or out-of-hours access apply; we show any access costs as a separate line.

Each quote covers the certified doorset, standard ironmongery, fitting, removal of the old door and a handover record; anything outside that scope is shown as a separate line before you accept.

Where school fire doors are needed

Typical uses for school fire doors in Hayes include care and nursing homes and GP surgeries and clinics.

London has the UK's largest concentration of purpose-built flats and high-rise residential blocks, so flat entrance doors, communal corridor doors and regulation 10 checks drive much of the demand.

  • Care and nursing homes
  • GP surgeries and clinics
  • Nurseries
  • Primary and secondary schools

What you get with each doorset

RatingFD30S typical; FD60S where compartmentation needs it
WidthsWide single and leaf-and-a-half for beds and wheelchairs
ProtectionKick plates, push plates, edge protection
Hold-openAlarm-linked hold-open and free-swing closers
GuidanceSector guidance such as BB100 (schools, England) and HTM 05-02 (healthcare)
Elevation drawing of school & healthcare fire doors

See the full specification and options for School & Healthcare Fire Doors

What happens next

  1. Share your FRA or inspection findings
  2. We confirm every door on site
  3. Fixed quote, certified doorsets only
  4. Fitted to the manufacturer's instructions, with photos

Common questions in Greater London

Which rules do school fire doors in Hayes need to meet?

They are specified to Approved Document B (England) and your fire risk assessment or fire strategy. We confirm the rating of each door at survey.

Can you work around tenants or staff in Hayes?

Yes. We phase work in occupied buildings and keep escape routes available. Each door is planned to be removed and replaced the same day; if that isn't possible, the opening is made secure and we tell you in advance.

Do you work for landlords and managing agents in Hayes?

Yes. We can schedule doors flat by flat, send quotes per property and invoice the managing agent or freeholder.

Do these doors need vision panels?

Doors across corridors normally do, for safeguarding and accessibility.

Neighbouring areas

Other products in Hayes

Get a fixed quote for your fire doors

Free measure survey. Certificate reference against every doorset.