- Approved Document B
- Statutory guidance on fire safety for building work in England (Wales publishes its own version). Volume 1 covers dwellings; Volume 2 covers other buildings.
- Approved Document M
- Guidance on access to and use of buildings. For doors it sets clear widths, vision panels and maximum opening forces.
- Approved Document Q
- Guidance on security in new dwellings in England, requiring doorsets that give access to a dwelling to meet PAS 24 or equivalent.
- BS 476-22
- The British test standard for fire resistance of non-loadbearing elements, including doors. It is the source of FD ratings and is due to be removed from Approved Document B on 2 September 2029.
- BS 476-31.1
- The British test for smoke leakage through doorsets at ambient temperature, behind the S in FD30S.
- BS 8214
- The code of practice for fire-resisting and smoke control doors. The 2026 edition, published in March 2026, covers timber, steel, glazed and composite doors.
- BS EN 1634-1
- The European fire resistance test for doorsets, leading to E and EI classifications under BS EN 13501-2.
- BS EN 1634-3
- The European smoke leakage test for doorsets, leading to Sa and S200 classifications.
- BS EN 13501-2
- The European classification standard for fire resistance, using codes such as E30, EI60 and E30 Sa.
- BS EN 1154
- The standard for controlled door closing devices such as overhead closers.
- BS EN 1155
- The standard for electrically powered hold-open devices that release a door when the fire alarm sounds.
- BS EN 1158
- The standard for door coordinators (selectors), which make pairs of doors close in the right order.
- BS EN 1125
- The standard for panic exit devices — push bars — for doors used by the public.
- BS EN 179
- The standard for emergency exit devices, such as push pads and levers, for doors used by trained staff.
- BS EN 1935
- The standard for single-axis hinges, including the grades used on fire doors.
- Building Safety Act 2022
- Legislation creating the Building Safety Regulator and a stricter regime for higher-risk buildings: 18 metres or seven storeys with at least two residential units.
- Certificate reference
- The number of the third-party certificate that covers a doorset. We put it on every quote so it can be checked.
- Compartment wall
- A fire-resisting wall dividing a building into compartments. Doors in compartment walls usually need the same rating as the wall.
- Door leaf
- The moving part of a door. A leaf alone is not a fire door — the rating belongs to the doorset.
- Door selector
- Another name for a door coordinator, which controls the closing sequence of a pair of doors with rebated meeting stiles.
- Doorset
- A complete assembly of leaf, frame, seals, hinges and hardware supplied and tested as one unit.
- E (integrity)
- The European classification for a construction's ability to stop flames and hot gases passing through. E30 means 30 minutes.
- EI (integrity and insulation)
- A European classification adding insulation: the unexposed face must stay below set temperature rises.
- FD rating
- The British shorthand for a fire door's integrity rating in minutes, for example FD30 or FD60.
- FD30S
- A 30-minute fire door that also restricts cold smoke, using tested smoke seals.
- Field of application
- The range of sizes, glazing and hardware a manufacturer's test evidence or assessment covers.
- Fire risk assessment
- The assessment a responsible person must carry out for non-domestic premises and the common parts of multi-occupied residential buildings.
- Fire Safety Act 2021
- Legislation confirming the Fire Safety Order covers the structure, external walls and flat entrance doors of multi-occupied residential buildings.
- Fire Safety Order
- The Regulatory Reform (Fire Safety) Order 2005, the main fire safety law for existing non-domestic premises in England and Wales.
- Fire strategy
- The design document that sets fire resistance and escape requirements for a building, including which doors need which rating.
- FIRAS
- A third-party certification scheme for installers of passive fire protection, including fire doors, operated by Warringtonfire.
- Flat entrance door
- The front door of a flat opening onto a shared corridor, lobby or stair, usually required to be FD30S and self-closing.
- Flush bolt
- A bolt recessed into the edge of a door leaf to hold an inactive leaf closed, usually on cupboard or plant room pairs.
- Free-swing closer
- A closer that lets a door move freely like an unclosed door until the fire alarm activates it.
- Golden thread
- The accurate, up-to-date information about a higher-risk building that must be kept under the Building Safety Act.
- Hold-open device
- An electromagnetic device that holds a fire door open and releases it on alarm.
- HMO
- A house in multiple occupation — a property let to people forming more than one household who share facilities.
- Intumescent seal
- A strip in the door edge or frame that swells in heat to seal the gap between leaf and frame.
- Ironmongery
- Door hardware: hinges, locks, latches, handles, closers, plates and seals.
- Leaf-and-a-half
- A pair of doors with one wide and one narrow leaf.
- LPS 1175
- A security standard from the Loss Prevention Certification Board that grades resistance to forced entry.
- Meeting stiles
- The vertical edges where the two leaves of a double door meet.
- PAS 24
- A UK security standard for doorsets and windows, commonly used for flat entrance and external doors.
- Q-Mark
- BM TRADA's third-party certification scheme, including fire door manufacture and installation.
- Regulation 10
- Part of the Fire Safety (England) Regulations 2022 requiring regular fire door checks in residential buildings with a storey above 11 metres.
- Regulation 38
- Part of the Building Regulations requiring fire safety information to be handed to the responsible person for relevant buildings in England.
- Responsible person
- The person with duties under the Fire Safety Order — usually the employer, owner or managing agent.
- Riser
- A vertical service shaft carrying cables or pipes between floors, closed off by fire-rated doors kept locked shut.
- Sa
- The European smoke control classification at ambient temperature, as in E30 Sa.
- Self-closing device
- A closer that returns a door to its closed and latched position from any angle of opening.
- Smoke seal
- A brush or blade seal that restricts the passage of cold smoke around a closed door.
- Third-party certification
- Independent ongoing certification of a product or installer by a UKAS-accredited body, beyond a one-off test.
- Threshold gap
- The gap under a fire door, set by the manufacturer's evidence and sometimes closed with a drop-down seal.
- Vision panel
- A glazed panel in a door leaf allowing people to see through. In a fire door it must use tested fire-resistant glass.
Fire door glossary
Plain-English definitions of the terms you'll meet in fire door specifications, surveys and regulations.