Complete certified doorsetsFree measure surveyEngland, Wales, Scotland & NI
Call 0800 088 6248
Fire Rated Doors
FD30E30 / EI3044mm leaf

FD30 Fire Doorsets in Halewood

We supply and fit FD30 fire doors in Halewood (L26) as complete certified doorsets — surveyed free, quoted door by door with each manufacturer's certificate reference, and fitted to the manufacturer's instructions.

From £750 per single doorset in Halewood, supplied & fitted, ex VAT

White painted flush timber fire door with overhead closer in an office corridor

Certified FD30 fire doors for Halewood

Getting FD30 fire doors right in Halewood means choosing a certified doorset for each opening and fitting it exactly as tested. That's the whole service: survey, schedule, certified doorset, careful installation and the paperwork to prove it.

Where possible we combine Halewood surveys with other visits in Merseyside, such as Speke and Garston, which helps keep survey dates flexible.

Which rules apply in Halewood?

Because Halewood is in England, the starting point is Approved Document B for the specification and the Fire Safety Order 2005 for ongoing duties. Blocks with a storey above 11 metres also fall under regulation 10 of the Fire Safety (England) Regulations 2022: communal fire doors checked at least every three months, flat front doors at least every year.

Guide prices in Halewood

Guide prices for FD30 fire doors in Halewood run from about £750 to £1,150 per single doorset, supplied and fitted, ex VAT. Size, glazing, finish and ironmongery move the price, and the survey quote is fixed.

Each quote covers the certified doorset, standard ironmongery, fitting, removal of the old door and a handover record; anything outside that scope is shown as a separate line before you accept.

Where FD30 fire doors are used in Halewood

In Halewood, FD30 fire doors are typically needed in plant rooms and stores and hotel corridors.

Liverpool's large stock of city-centre apartments and student blocks is matched by Victorian conversions across Wirral, Sefton and St Helens.

  • Plant rooms and stores
  • Hotel corridors
  • HMO bedrooms and kitchens
  • Offices and retail back-of-house

FD30 Fire Doorsets: key specification

Fire resistance30 minutes integrity (FD30 / E30); EI30 where insulation is specified
Typical leaf44mm timber, flush or with vision panel
Test evidenceBS 476-22 or BS EN 1634-1, plus the manufacturer's field of application
CloserOverhead closer to BS EN 1154 (except locked cupboards)
HingesThree CE/UKCA-marked hinges to BS EN 1935, grade 13 typical
Elevation drawing of fd30 fire doorsets

See the full specification and options for FD30 Fire Doorsets

What happens next

  1. Request a quote online or call
  2. Survey: sizes, ratings, hardware and condition
  3. Quote with each doorset's certification
  4. Phased fitting and handover records

Common questions in Merseyside

Which rules do FD30 fire doors in Halewood need to meet?

They are specified to Approved Document B (England) and your fire risk assessment or fire strategy. We confirm the rating of each door at survey.

Do you remove the old doors?

Yes. Removal and disposal of the old door and frame is included when we replace a doorset in Halewood.

How quickly can you survey in Halewood?

We arrange surveys around your access needs and, where possible, combine Halewood visits with other work in Merseyside. Tell us your preferred dates when you enquire.

Is FD30 the same as E30?

Broadly, yes. FD30 comes from the British test (BS 476-22); E30 is the European classification from BS EN 1634-1. Both mean 30 minutes of integrity. EI30 adds insulation, which some locations and glazed doors need.

Neighbouring areas

Other fire doors in Halewood

Get a fixed quote for your fire doors

Free measure survey. Certificate reference against every doorset.