We supply and fit FD30 fire doors in Stamford Hill (N16) as complete certified doorsets — with a free measure survey, a fixed itemised quote listing every certificate reference, and installation exactly as tested.

From £750 per single doorset in Stamford Hill, supplied & fitted, ex VAT

White painted flush timber fire door with overhead closer in an office corridor

FD30 Fire Doorsets for Stamford Hill buildings

Fire Rated Doors supplies and fits FD30 fire doors in Stamford Hill, Greater London. Whether it's a single replacement or every door in a block, we start by surveying the openings and end with a handover pack listing each doorset and its certificate reference.

Whether your building is in central Stamford Hill or on its edges towards Highbury, survey and fitting dates are arranged around your access needs, with occupied buildings worked in planned phases.

Regulations for FD30 fire doors in Greater London

New and replacement fire doors in Stamford Hill are specified under the Building Regulations 2010 and Approved Document B. In workplaces and the common parts of blocks of flats, the Regulatory Reform (Fire Safety) Order 2005 makes the responsible person keep fire doors in working order, and in residential buildings with a storey above 11 metres regulation 10 of the Fire Safety (England) Regulations 2022 adds quarterly checks of communal doors and annual checks of flat entrance doors.

FD30 fire doors prices in Stamford Hill

Guide prices for FD30 fire doors in Stamford Hill run from about £750 to £1,150 per single doorset, supplied and fitted, ex VAT. Size, glazing, finish and ironmongery move the price, and the survey quote is fixed.

Central and inner London work can cost a little more where parking, loading restrictions or out-of-hours access apply; we show any access costs as a separate line.

Each quote covers the certified doorset, standard ironmongery, fitting, removal of the old door and a handover record; anything outside that scope is shown as a separate line before you accept.

Where FD30 fire doors are needed

Wherever they are in Stamford Hill, FD30 fire doors are most often specified for offices and retail back-of-house and HMO bedrooms and kitchens.

London has the UK's largest concentration of purpose-built flats and high-rise residential blocks, so flat entrance doors, communal corridor doors and regulation 10 checks drive much of the demand.

  • Offices and retail back-of-house
  • HMO bedrooms and kitchens
  • Hotel corridors
  • Plant rooms and stores

What's in the doorset

Fire resistance30 minutes integrity (FD30 / E30); EI30 where insulation is specified
Typical leaf44mm timber, flush or with vision panel
Test evidenceBS 476-22 or BS EN 1634-1, plus the manufacturer's field of application
CloserOverhead closer to BS EN 1154 (except locked cupboards)
HingesThree CE/UKCA-marked hinges to BS EN 1935, grade 13 typical
Elevation drawing of fd30 fire doorsets

See the full specification and options for FD30 Fire Doorsets

What happens next

  1. Tell us about the doors — photos help
  2. Free measure survey at your Stamford Hill property
  3. Door-by-door schedule and fixed price
  4. Installation and handover pack

Your questions answered

How quickly can you survey in Stamford Hill?

We arrange surveys around your access needs and, where possible, combine Stamford Hill visits with other work in Greater London. Tell us your preferred dates when you enquire.

Can you work around tenants or staff in Stamford Hill?

Yes. We phase work in occupied buildings and keep escape routes available. Each door is planned to be removed and replaced the same day; if that isn't possible, the opening is made secure and we tell you in advance.

Is the survey in Stamford Hill free?

Yes. We measure and schedule your doors at no cost and send a fixed, itemised quote.

Is FD30 the same as E30?

Broadly, yes. FD30 comes from the British test (BS 476-22); E30 is the European classification from BS EN 1634-1. Both mean 30 minutes of integrity. EI30 adds insulation, which some locations and glazed doors need.